tickets»view/86

Latest Ticket for ROD ID 71

Ticket rod id Author Description Action Repaired edit
86 71 Alex ROD Failed initial compression test, in e-06 slot 12. ROD debug regs reported a LookUp overflow; searchResult fifo overflow. This was present at all times top and bottom even after a reboot, taken to 104 for testing. In 104 the ROD passed a rod_loop_data_test of 1000 with full compression (f7.out). No LookUp overflow was reported although TTC overflow was reported after a reboot? The ROD also appears unable to internally lock. In general any ROD which is sensitive to the clock it is provided has issues in e-06, see DDR init faults of 50 and 52. Also ROD 68, e-06 slot 18 top has the same fault as above, see next ticket. edit