rods»view/135

Status Summary for ROD ID 135

<<Prev | Next>>

Test NameStatusNotesModified
Board Status 1 Sent to Dorigo for NSE x-ray. Looking at the logs this board did pass NSE both top and bottom initially? (Alex 13/2/13) ROD fails to QPLL lock on internal mode, when next to the ttc locks fine. Top NSE replaced by Dorigo Passed nse tests after replacement. 28-10-2014
nse lookup 1
Passed after nse replacement
22-11-2013
nse lookup 0
CG: Can't talk to top NSE? How did this get set to pass before?
18-05-2012
nse lookup 1
13-06-2011
assembly 1
13-06-2011
ddr reset 1
13-06-2011
test fifo 1
13-06-2011
ttc connectivity 1
13-06-2011
qpll lock 1
10-06-2011
patch panel 1
10-06-2011
slink 1
10-06-2011
optical loop 1
10-06-2011
sram 1
09-06-2011
nse communication 1
09-06-2011
dram 1
08-06-2011
loop data 1
08-06-2011
V4B temp 1
17-05-2011
V4T temp 1
17-05-2011
I3V proms 1
17-05-2011
I5V proms 1
17-05-2011
connectivity 1
17-05-2011
proms load 1
17-05-2011
I3V initial 1
17-05-2011
I5V_initial 1
17-05-2011
U82 1
17-05-2011
U81 1
17-05-2011
U35 1
17-05-2011
U34 1
17-05-2011
U33 1
17-05-2011
U32 1
17-05-2011
U31 1
17-05-2011
fuses 1
13-05-2011