rods»view/134

Status Summary for ROD ID 134

<<Prev | Next>>

Test NameStatusNotesModified
Board Status ROD fails to QPLL lock on internal mode, when next to the ttc locks fine. 13-06-2011
assembly 1
13-06-2011
ddr reset 1
13-06-2011
test fifo 1
13-06-2011
ttc connectivity 1
13-06-2011
qpll lock 1
10-06-2011
patch panel 1
10-06-2011
slink 0
bottom half passed, top half failed. the filar scope does not see anything when executing rod_send_self_l1a. The rod_loop_data_test returns Error spyfifocnt[ii]: 0
10-06-2011
optical loop 1
10-06-2011
sram 1
09-06-2011
nse communication 1
09-06-2011
dram 0
Bottom half passed. Top half failed.
08-06-2011
loop data 0
Bottom half passed Top half failed. When running rod_test_dma "No data in buffer" appears, and when running rod_loop_data_test "Error spyfifocnt[ii]: 0" appears for all events.
08-06-2011
V4B temp 1
17-05-2011
V4T temp 1
17-05-2011
I3V proms 1
17-05-2011
I5V proms 1
17-05-2011
proms load 1
17-05-2011
I3V initial 1
17-05-2011
I5V_initial 1
17-05-2011
U82 1
17-05-2011
U81 1
17-05-2011
U35 1
17-05-2011
U34 1
17-05-2011
U33 1
17-05-2011
U32 1
17-05-2011
U31 1
17-05-2011
connectivity 1
17-05-2011
fuses 1
13-05-2011