rods»view/121

Status Summary for ROD ID 121

<<Prev | Next>>

Test NameStatusNotesModified
Board Status Sent to Dorigo for NSE x-ray. ZG6/11/14: top passes high rate test, bottom flaky channels 0x15 and 0x29. Feb, 2015: Components replaced (C378,C418). 29-04-2015
sram 1
Passed SRAM test
24-11-2013
nse communication 1
Passed after sending to Dorigo
24-11-2013
assembly 1
27-05-2011
ddr reset 1
27-05-2011
optical loop 1
27-05-2011
patch panel 1
27-05-2011
qpll lock 1
27-05-2011
ttc connectivity 1
27-05-2011
slink 1
27-05-2011
test fifo 1
27-05-2011
nse communication 0
top half passed top bottom failed
25-05-2011
sram 0
top half passed the test bottom half failed: fails for all txs, bit errors histogram for all bits ~ 65k, for a given test, "Data Read" remains the same for all addresses, the value of "Data Read" changes from test to test.
25-05-2011
dram 1
25-05-2011
loop data 1
25-05-2011
V4B temp 1
16-05-2011
V4T temp 1
16-05-2011
I3V proms 1
16-05-2011
I5V proms 1
16-05-2011
connectivity 1
16-05-2011
proms load 1
16-05-2011
U82 1
16-05-2011
U81 1
16-05-2011
U35 1
16-05-2011
U34 1
16-05-2011
U33 1
16-05-2011
U32 1
16-05-2011
U31 1
16-05-2011
I3V initial 1
16-05-2011
I5V_initial 1
16-05-2011
fuses 1
13-05-2011