rods»view/104

Status Summary for ROD ID 104

tickets

<<Prev | Next>>

Test NameStatusNotesModified
Board Status 1 Chip U3 replaced, locks to TTC fine. -AC 6/11/08 Chip U3 has pins 2&3 shorted internally. The chip has been removed, waiting for a replacement to be ordered. -AC 05/30/08 Replaced QPLL Crystal X3, still unable to get a qpll lock to TTC. Gets internal lock just fine. -AC 5/2/08V4 temps measured after ~5min running instead of right away -Bill 21-07-2008
fuses 1
17-06-2008
U31 1
17-06-2008
U32 1
17-06-2008
U33 1
17-06-2008
U34 1
17-06-2008
U35 1
17-06-2008
U81 1
17-06-2008
U82 1
17-06-2008
I5V_initial 1
17-06-2008
I3V initial 1
17-06-2008
proms load 1
17-06-2008
I5V proms 1
17-06-2008
I3V proms 1
17-06-2008
V4T temp 1
17-06-2008
V4B temp 1
17-06-2008
connectivity 1
17-06-2008
loop data 1
17-06-2008
slink 1
17-06-2008
dram 1
17-06-2008
nse communication 1
Passed nse test 40 times when re-tested, original failure probably user error or non-locked qpll (04/6/08 alex).
17-06-2008
sram
17-06-2008
optical loop 1
17-06-2008
patch panel 1
17-06-2008
qpll lock 1
17-06-2008
ttc connectivity 1
Will not lock to TTC.
17-06-2008
test fifo 1
17-06-2008
ddr reset
17-06-2008
assembly 0
U13, FIN 1101
17-06-2008